Pair Count |
Nominal Conductor Diameter |
Nominal Outside Diameter |
Approx Cable Weight |
Standard Length |
|||
AWG |
mm |
Inch |
Kg/305m |
Lbs./1KFt. |
m |
Ft. |
|
4 |
24 |
7.5 |
0.295 |
16 |
35.3 |
305 |
1000 |
|
[Ohms/100m] [ % ] [nF/100m] [pF/100m] [Ohms] |
Max. 9.38 Max. 5 Max. 5.6 Max. 330 100±6 100±15 100±22 100±32 |
Frequency (MHz) |
RL (Min. dB) |
Attenuation (Max. dB/100m) |
NEXT (Min. dB) |
PS-NEXT (Min. dB) |
ACR (Min. dB) |
PS-ACR (Min. dB) |
ELFEXT (Min. dB/100m) |
PS-ELFEXT (Min. dB/100m) |
0.772 1 4 8 10 16 20 25 31.25 62.5 100 200 250 |
- 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.0 17.3 |
1.8 2.0 3.8 5.3 6.0 7.6 8.5 9.5 10.7 15.4 19.8 29.0 32.8 |
76.0 74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8 38.3 |
74.0 72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8 36.3 |
74.2 72.3 61.5 55.5 53.3 48.6 46.3 43.8 41.2 32.0 24.5 10.8 5.5 |
72.2 70.3 59.5 53.5 51.3 46.6 44.3 41.8 39.2 30.0 22.5 8.8 3.5 |
70.0 67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8 19.8 |
67.0 64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 18.8 16.8 |
Part Number |
Jacket |
Flame Rating |
Jacket Color |
Length |
Packing |
|
M |
FEET |
|||||
F006004-XBL2 F006004-XGY2 F006004-XWH2 |
PVC PVC PVC |
CMX CMX CMX |
Blue Gray White |
305 305 305 |
1000 1000 1000 |
Reel Reel Reel |
F006004-MBL2 F006004-MGY2 F006004-MWH2 |
PVC PVC PVC |
CM CM CM |
Blue Gray White |
305 305 305 |
1000 1000 1000 |
Reel Reel Reel |
F006004-RBL2 F006004-RGY2 F006004-RWH2 |
PVC PVC PVC |
CMR CMR CMR |
Blue Gray White |
305 305 305 |
1000 1000 1000 |
Reel Reel Reel |
F006004-LBL2 F006004-LGY2 F006004-LWH2 |
LSZH LSZH LSZH |
CMX CMX CMX |
Blue Gray White |
305 305 305 |
1000 1000 1000 |
Reel Reel Reel |
* Also available in Red, Yellow, Orange, Green, Natural or Purple.