Новые высокотемпературные провода SuperLinx
Выпускаются небольшими партиями/ длинами, с маркировкой и окраской
COMPLIANCE WITH
CABLE STANDARDS
CONSTRUCTION
Conductor: |
23 AWG bare copper |
Insulation: |
Foam-Skin polyolefin. Nominal diameter over insulation 1.35 mm |
Pairs: |
Two wires twisted into pairs with different lays (lay direction left) |
Pairs color code: |
white-blue, white-orange, white-green and white-brown |
Cabling: |
4 twisted pairs cabled to form the cable core |
Shielding: |
Individual aluminum-polyester foil over each pair. Aluminum facing outwards. Optional 26 AWG drain wire in the cable core center |
Outer jacket material: |
HFFR (LS0H) |
TRANSMISSION PROPERTIES
Freq. MHz |
Attenuation dB/100m |
NEXT pp dB |
ELFEXT pp dB/100m |
Return Loss dB |
Max. |
Min. |
Min. |
Min. |
|
4 |
3.8 |
66 |
56 |
23.0 |
10 |
5.9 |
60 |
48 |
25.0 |
16 |
7.5 |
57 |
44 |
25.0 |
20 |
8.4 |
56 |
42 |
25.0 |
31.25 |
10.5 |
53 |
38 |
23.3 |
62.5 |
15.0 |
48 |
32 |
21.5 |
100 |
19.1 |
45 |
28 |
20.1 |
200 |
27.6 |
41 |
22 |
18.0 |
250 |
31.1 |
39 |
20 |
17.3 |
500 |
45.3 |
35 |
14 |
17.3 |
PSNEXT=pair to pair NEXT-3
PSELFEXT=pair to pair ELFEXT-3
ACR=pair to pair NEXT-Attenuation [dB/100m]
PSACR=pair to pair ACR-3 [dB/100m]
HIGH FREQUENCY ELECTRICAL PROPERTIES
Mean characteristic impedance (4-100 MHz) | Ω |
100 ± 5 |
Nom. velocity of propagation |
|
0.78C |
Phase delay @ 500 MHz |
ns/100 m |
<536 |
Delay skew (4-500 MHz) |
ns/100 m |
<30 |
Transfer Impedance @ 30 MHz |
mΩ/m |
< 30 |
LOW FREQUENCY AND DC ELECTRICAL PROPERTIES
Mutual Capacitance @ 1 KHz | nF/km |
45 |
DC resistance |
Ω/km |
<75 |
Capacitance unbalance to ground |
pF/km |
<1500 |
Resistance unbalance |
% |
<2 |
Insulation resistance |
MΩ.m |
> 5000 |
Dielectric strength |
kV d.c./1min |
1 |
Operating voltage |
Volts |
60 |
ENVIRONMENTAL AND OTHER PROPERTIES
Operating temperature range | °C |
-20 to +60 |
Installation temperature range |
°C |
-5 to +50 |
Max installation tensile load |
kg |
8 |
Min installation bend radius |
|
8*cable OD |
Min long term bend radius |
|
8*cable OD |
Flame retardancy (all cables) |
|
IEC 60332-1 UL - 1581 VW- 1 |
Halogen content (HFFR cables) |
|
IEC 60754-2 |
Smoke emission (HFFR cables) |
|
IEC 61034 |
MARKING
Cables are marked as follows
Synergy Cables SuperLan 6, Part Number, STP 4x2x23 AWG 500 MHz, HFFR, IEC 61156-5 Cat. 6, IEC 60332-1, RoHS, length in m
or per customer request.
ORDERING
Consult the standard cable Part Numbers Table. Standard packaging: 500 meters on a wooden drum. Other packaging options, constructions and materials may be available. Please contact the Synergy Cables Marketing Department.
Cable Part Numbers and Description
Part Number |
Cable Geometry |
No. of Pairs |
Wire Gage |
Weight |
Dimension |
Jacket |
Jacket * |
Caloric |
611356 |
Circular simplex |
4 |
24 |
52 |
7.1 |
HFFR |
7032 Grey |
450 |
611357 |
Fig. 8 Duplex |
8 |
24 |
110 |
7.1x15.0 |
HFFR |
7032 Grey |
900 |
Other jacket colors are available. Please specify.