GENERAL DESCRIPTION AND APPLICATION
STANDARDS
CONSTRUCTION
ELECTRICAL AND TRANSMISSION PROPERTIES
See properties table next page.
MECHANICAL AND ENVIRONMENTAL PROPERTIES
Per EIA/TIA-568B and UL-444.
When used outdoor, care must be taken to prevent water and excessive humidity from entering the cable.
FLAME RETARDANCY
Meets customer’s request per either one of the following standards:
MARKING
Cables are marked as follows:
Synergy Cables --- Cable Code --- RoHS ---Length in Meters
or per customer request.
CABLE PART NUMBERS, DIMENSIONS AND WEIGHTS
See detailed cable list.
ORDERING
According to the cable list. Standard cable lengths vary with pair count. Other constructions, color codes and materials may be available. Please contact the Synergy Cables Marketing Department.
Electrical and Transmission Properties
|
Specification |
Unit |
Max DC Resistance |
9.38 |
Ω/100m |
Max Resistance Unbalance |
5 |
% |
Max Capacitance Unbalance - pair-to-ground @ 1kHz |
330 |
pF/100m |
Characteristic Impedance @ 1-16 MHz |
85 - 115 |
Ω |
Min worst pair Structural Return Loss (SRL): |
|
|
Up to 10 MHz |
12 |
dB |
Between 10 and 16 MHz |
10 |
dB |
Max Attenuation at 20°C @ 64 kHz |
0.9 |
dB/100m |
@ 256 kHz |
1.3 |
|
@ 512 kHz |
1.8 |
|
@ 772 kHz |
2.2 |
|
@ 1 MHz |
2.6 |
|
@ 4 MHz |
5.6 |
|
@ 8 MHz |
8.5 |
|
@ 10 MHz |
9.7 |
|
@ 16 MHz |
13.1 |
|
Min worst pair to pair NEXT Loss @ 772 kHz |
43 |
dB |
@ 1 MHz |
41 |
|
@ 4 MHz |
32 |
|
@ 8 MHz |
28 |
|
@ 10 MHz |
26 |
|
@ 16 MHz |
23 |
|
Min Relative Velocity of Propagation @ 10 MHz |
0.585 |
|
1. All values measured at 20°C.
2.
Requirements as per IEC-61156-4
Cable List
Synergy Part Number |
Cable Code |
Number of Pairs |
Nominal Jacket Thickness |
Maximum Outer Diameter |
Nominal Weight |
PVC Jacket, Indoor |
|||||
4101625-D |
10*2*0.5/0.9-B-SO-V-C3 |
10 |
0.9 |
9.5 |
77 |
410165-D |
25*2*0.5/0.9-B-SO-V-C3 |
25 |
0.9 |
12.5 |
155 |
407685-D |
50*2*0.5/0.9-B-SO-V-C3 |
50 |
1.0 |
17.0 |
260 |
407690-D |
100*2*0.5/0.9-B-SO-V-C3 |
100 |
1.1 |
21.5 |
530 |
407697-D |
200*2*0.5/0.9-B-SO-V-C3 |
200 |
1.2 |
29.5 |
1100 |
407694-D |
50*2*0.5/0.9-B-SO-H-C3 100 OH |
300 |
1.3 |
33.5 |
1550 |
HFFR Jacket, Indoor & Outdoor (*) |
|||||
4076860-D |
10*2*0.5/0.91-B-SO-H-C3 |
10 |
0.9 |
10.0 |
80 |
4076830-D |
20*2*0.5/0.9-B-SO-H-C3 |
25 |
0.9 |
14.0 |
150 |
407694-D |
50*2*0.5/0.9-B-SO-H-C3 |
50 |
1.1 |
16.5 |
280 |
4076916-D |
100*2*0.5/0.9-B-SO-H-C3 |
100 |
1.4 |
21.5 |
530 |
4076914-D |
200*2*0.5/0.91-B-SO-H-C3 |
200 |
1.7 |
30.0 |
900 |
40769210-D |
300*2*0.5/0.91-B-SO-H-C3 |
300 |
1.7 |
36.0 |
1300 |
PVC Jacket, Outdoor (*) |
|||||
4101555-D |
10*2*0.5/0.91-B-SO-P-C3 |
10 |
0.9 |
9.5 |
80 |
4101565-D |
25*2*0.5/0.91-B-SO-P-C3 |
25 |
0.9 |
13.0 |
150 |
4101594-D |
50*2*0.5/0.91-B-SO-P-C3 |
50 |
1.0 |
16.0 |
280 |
4101598-D |
100*2*0.5/0.91-B-SO-P-C3 |
100 |
1.1 |
21.5 |
550 |
4101601-D |
200*2*0.5/0.91-B-SO-P-C3 |
200 |
1.2 |
28.5 |
1050 |
4101606-D |
300*2*0.5/0.91-B-SO-P-C3 |
300 |
1.3 |
34.5 |
1550 |
(*) Outdoor data cables should not be immersed in water or exposed to excessive humidity.
All cable dimensions and weights are subject to normal manufacturing tolerances.