Вся информация на сайте предназначена только для специалистов кабельной отрасли, энергетики и электротехники.
+
 

Cat 7A SSTP Horizontal Cables, 1000 MHz 4x2x23 AWG and 2x(4x2x23 AWG)

 image

COMPLIANCE WITH

  • ISO/IEC 11801 draft, Class FA
  • CENELEC EN 50173:2002
  • IEC-60332-1
  • UL 1581 VW-1
  • IEEE 802.3an 10GBASE-T

CABLE STANDARDS

  • IEC 61156-5 Cat. 7A NCD 5.2007
  • EN 50288-4-1
  • IEC 60332-1

CONSTRUCTION

Conductor:

23 AWG bare copper

Insulation: 

Foam-Skin polyolefin. Nominal diameter over insulation 1.41 mm

Pairs:

Two wires twisted into pairs with different lays (lay direction left)

Pairs color code:

white-blue, white-orange, white-green and white-brown

Cabling:

4 twisted pairs cabled to form the cable core

Shielding:

Individual aluminum-polyester foil over each pair and overall braided wires shield over the cabled pairs:

  1. Foil shielding: polyester aluminum tape, aluminum side facing outwards
  2. Drain wire: optional 26 AWG tinned copper in the cable core center
  3. Braided copper shielding: tinned copper wires

Outer jacket material:

HFFR (LS0H)

TRANSMISSION PROPERTIES

Freq. MHz

Attenuation dB/100m

NEXT pp dB

ELFEXT pp dB/100m

Return Loss dB

Max.

Min.

Min.

Min.

4

3.7

78

78

23.0

10

5.8

78

74

25.0

16

7.3

78

70

25.0

20

8.2

78

68

25.0

31.25

10.3

78

64

23.6

62.5

14.6

75

58

21.5

100

18.5

72

54

20.1

300

32.7

65

44

17.3

600

47.1

61

38

17.3

1000

61.9

57

34

17.3

PSNEXT=pair to pair NEXT-3
PSELFEXT=pair to pair ELFEXT-3
ACR=pair to pair NEXT-Attenuation [dB/100m]
PSACR=pair to pair ACR-3 [dB/100m]

HIGH FREQUENCY ELECTRICAL PROPERTIES

Mean characteristic impedance (4-100 MHz)

Ω

100 ± 5

Nom. velocity of propagation

 

0.78C

Phase delay @ 1000 MHz

ns/100 m

<536

Delay skew (4-1000 MHz)

ns/100 m

<25

Transfer Impedance @ 30 MHz

mΩ/m

< 30

LOW FREQUENCY AND DC  ELECTRICAL PROPERTIES

Mutual Capacitance @ 1 KHz

nF/km

45

DC resistance

Ω/km

<75

Capacitance unbalance to ground

pF/km

<1500

Resistance unbalance

%

<2

Insulation resistance

MΩ.m

> 5000

Dielectric strength

kV d.c./1min

1

Operating voltage

Volts

60

ENVIRONMENTAL AND OTHER PROPERTIES

Operating temperature range

°C

-20 to +60

Installation temperature range

°C

-5 to +50

Max installation tensile load

kg

8

Min installation bend radius

 

12*cable OD

Min long term bend radius

 

8*cable OD

Flame retardancy (all cables)

 

IEC 60332-1
UL - 1581 VW- 1

Halogen content (HFFR cables)

 

IEC 60754-2

Smoke emission (HFFR cables)

 

IEC 61034

MARKING

Cables are marked as follows
Synergy Cables SuperLan 7, Part Number, SSTP 4x2x23 AWG 1000 MHz,HFFR, IEC 61156-5 Cat. 7, IEC 60332-1, RoHS, length in m
or per customer request.


ORDERING

Standard packaging: 500 meters on a wooden drum. Other packaging options, constructions and materials may be available. Please contact the Synergy Cables Marketing Department.

Cable Part Numbers and Description

Part Number

Cable Geometry

No. of Pairs

Wire Gage

Weight
kg/km

Dimension
mm

Jacket
Material

Jacket
RAL/color

Caloric
Value
MJoule/km

611592

Circular simplex

4

23

  61

7.5

HFFR

3000 Red

450

611713

Fig. “8” duplex

8

23

124

7.7x16.0

HFFR

3000 Red

 900

Other jacket colors are available. Please specify.